DF300M Series

The DF300M Series is a low-profile, 300W, Open-frame power supply.  Size:  3.0″ x 5.0″ x 1.24″ (76.2 x 127 x 31.5 mm).  It is safety approved for ITE and Medical (MOOP and 2X MOPP) applications.

With an expanded temperature range of -20ºC to 70ºC (see derating curve), built-in +5V/1A standby power, a 24V/0.2A fan output and remote control On/Off functionality, the high-efficiency design of the DF300M Series delivers 250W @ 50ºC via convection coolind and 300W @ 50ºC with 11 CFM of cooling air.  The DF300M Series is the ideal choice for your high-power Medical and ITE equipment applications.

Features

  • Built-in +5V Standby Power
  • Built-in Remote Control Function
  • Ultra Slim with only 1.24″ Height
  • -20ºC  to 70ºC Convection Cooling
  • 92% Effiency (typ.)
  • Touch Current:  <100μA
  • 2X MOPP Approved Per IEC/EN 60601-1, (Ed. 3.1)
  • 2-Year Warranty

Applications 

  • Medical
  • ITE
  • Laboratory Equipment
  • Other Applications
wdt_ID Part No. Safety Input Outlook Output Voltage Wattage Size (mm) Size (in) EMI Standby Loss PFC PDF SPECS
1 DF300M-120 IT -UL/EN 60950-1, Medical -UL/EN 60601-1 0-264 VAC Open Frame Single 12V 300W 76.2 x 127.0 x 31.5 mm 3.0 x 5.0 x 1.24 in. Class B <0.5W None https://www.tri-mag.com/wp-content/uploads/2023/10/DF300M-Datasheet.pdf
2 DF300M-240 IT -UL/EN 60950-1, Medical -UL/EN 60601-1 0-264 VAC Open Frame Single 24V 300W 76.2 x 127.0 x 31.5 mm 3.0 x 5.0 x 1.24 in. Class B <0.2W None https://www.tri-mag.com/wp-content/uploads/2023/10/DF300M-Datasheet.pdf
3 DF300M-480 IT -UL/EN 60950-1, Medical -UL/EN 60601-1 0-264 VAC Open Frame Single 48V 300W 76.2 x 127.0 x 31.5 mm 3.0 x 5.0 x 1.24 in. Class B <0.2W None https://www.tri-mag.com/wp-content/uploads/2023/10/DF300M-Datasheet.pdf

NOTES: Contact factory for Safety Agency Approved status.

  1. Each output can provide up to peak load temporarily. Continuous operation at greater than rated load is not allowed.
  2. At factory, in 60% rated load condition, each output is checked to be within voltage accuracy.
  3. Line regulation is defined by changing ± 10% of input voltage from nominal line at rated load.
  4. Load regulation is defined by changing ± 40% of measured output load from 60% rated load.
  5. The ripple and noise is measured by using a 15MHz bandwidth limited oscilloscope. Each output is terminated with a 0.47 µF capacitor at rated load and nominal line.
  6. Hold up time is measured from the end of the last charging pulse to the time when the main output drops down to 95% output voltage at rated load and nominal line.
  7. Efficiency is measured at rated load.

Contact us today, and have all your power supply needs met fast.