DGK060/DGK060M Series
The DGK060 series power supply is a 60-watt and Medical-approved unit in a 2” X 4” footprint with a power density of 7.7W/cu in. The DGK060 is Green Energy complaint and has an efficiency of 90% typical. The DGK060M medical versions provide 2xMOPP isolation and a touch current <100μA. Both the ITE and Medical versions are available with output voltages ranging from 12V to 60V.
Features
- ITE/Medical applications
- Universal input 90VAC to 264VAC
- Cost effective
- Green Power
- Small size
- Single output
Applications
- ITE/Medical application
- Telecommunication
- PCB power
- Battery charging system
wdt_ID | Part No. | Safety | Input | Type | Output | Voltage | Wattage | Size (mm) | Size (in) | EMI | Standby Loss | PFC | PDF SPECS | 3D PDF | 3D CAD IGS/STEP |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | DGK060-7 | IT -UL/EN 60950-1 | 90 - 264 Vac | Open-Frame | Single | 12V | 60W | 50.8 x 101.6 mm | 2.0 x 4.0 in | Class B | <0.5W | None | PDF SPECS | 3D PDF | 3D CAD IGS/STEP |
2 | DGK060-8 | IT -UL/EN 60950-1 | 90 - 264 Vac | Open-Frame | Single | 15V | 60W | 50.8 x 101.6 mm | 2.0 x 4.0 in | Class B | <0.5W | None | PDF SPECS | 3D PDF | 3D CAD IGS/STEP |
3 | DGK060-9 | IT -UL/EN 60950-1 | 90 - 264 Vac | Open-Frame | Single | 24V | 60W | 50.8 x 101.6 mm | 2.0 x 4.0 in | Class B | <0.5W | None | PDF SPECS | 3D PDF | 3D CAD IGS/STEP |
4 | DGK060-14 | IT -UL/EN 60950-1 | 90 - 264 Vac | Open-Frame | Single | 48V | 60W | 50.8 x 101.6 mm | 2.0 x 4.0 in | Class B | <0.5W | None | PDF SPECS | 3D PDF | 3D CAD IGS/STEP |
5 | DGK060-G | IT -UL/EN 60950-1 | 90 - 264 Vac | Open-Frame | Single | 28V | 60W | 50.8 x 101.6 mm | 2.0 x 4.0 in | Class B | <0.5W | None | PDF SPECS | 3D PDF | 3D CAD IGS/STEP |
6 | DGK060-H | IT -UL/EN 60950-1 | 90 - 264 Vac | Open-Frame | Single | 60V | 60W | 50.8 x 101.6 mm | 2.0 x 4.0 in | Class B | <0.5W | None | PDF SPECS | 3D PDF | 3D CAD IGS/STEP |
7 | DGK060-J | IT -UL/EN 60950-1 | 90 - 264 Vac | Open-Frame | Single | 36V | 60W | 50.8 x 101.6 mm | 2.0 x 4.0 in | Class B | <0.5W | None | PDF SPECS | 3D PDF | 3D CAD IGS/STEP |
8 | DGK060M-14 | IT -UL/EN 60950-1, Medical -UL/EN 60601-1 | 90 - 264 Vac | Open-Frame | Single | 48V | 60W | 50.8 x 101.6 mm | 2.0 x 4.0 in | Class B | <0.5W | None | PDF SPECS | 3D PDF | 3D CAD IGS/STEP |
9 | DGK060M-7 | IT -UL/EN 60950-1, Medical -UL/EN 60601-1 | 90 - 264 Vac | Open-Frame | Single | 12V | 60W | 50.8 x 101.6 mm | 2.0 x 4.0 in | Class B | <0.5W | None | PDF SPECS | 3D PDF | 3D CAD IGS/STEP |
10 | DGK060M-8 | IT -UL/EN 60950-1, Medical -UL/EN 60601-1 | 90 - 264 Vac | Open-Frame | Single | 15V | 60W | 50.8 x 101.6 mm | 2.0 x 4.0 in | Class B | <0.5W | None | PDF SPECS | 3D PDF | 3D CAD IGS/STEP |
11 | DGK060M-9 | IT -UL/EN 60950-1, Medical -UL/EN 60601-1 | 90 - 264 Vac | Open-Frame | Single | 24V | 60W | 50.8 x 101.6 mm | 2.0 x 4.0 in | Class B | <0.5W | None | PDF SPECS | 3D PDF | 3D CAD IGS/STEP |
12 | DGK060M-G | IT -UL/EN 60950-1, Medical -UL/EN 60601-1 | 90 - 264 Vac | Open-Frame | Single | 28V | 60W | 50.8 x 101.6 mm | 2.0 x 4.0 in | Class B | <0.5W | None | PDF SPECS | 3D PDF | 3D CAD IGS/STEP |
13 | DGK060M-H | IT -UL/EN 60950-1, Medical -UL/EN 60601-1 | 90 - 264 Vac | Open-Frame | Single | 60V | 60W | 50.8 x 101.6 mm | 2.0 x 4.0 in | Class B | <0.5W | None | PDF SPECS | 3D PDF | 3D CAD IGS/STEP |
14 | DGK060M-J | IT -UL/EN 60950-1, Medical -UL/EN 60601-1 | 90 - 264 Vac | Open-Frame | Single | 36V | 60W | 50.8 x 101.6 mm | 2.0 x 4.0 in | Class B | <0.5W | None | PDF SPECS | 3D PDF | 3D CAD IGS/STEP |
NOTES: Contact factory for Safety Agency Approved status.
- Each output can provide up to max load separately when the power supply starts up. Exceeding the max. output power continuously is not allowed.
- At factory, in 60% rated load condition, each output is checked to be within voltage accuracy.
- Line regulation is defined by changing ± 10% of input voltage from nominal line at rated load.
- Load regulation is defined by changing ± 40% of measured output load from 60% rated load at another output set to 60% rated load.
- The ripple and noise is measured by using a 15MHz bandwidth limited oscilloscope. Each output is terminated with a 0.47 µF capacitor at rated load and nominal line.
- Hold up time is measured from the end of the last charging pulse to the time when the main output drops down to the low limit output of the main output at rated load and nominal line.
- Efficiency is measured at rated load and nominal load.