DGK060/DGK060M Series

DGK060

The DGK060 series power supply is a 60-watt and Medical-approved unit in a 2” X 4” footprint with a power density of 7.7W/cu in. The DGK060 is Green Energy complaint and has an efficiency of 90% typical.  The DGK060M medical versions provide 2xMOPP isolation and a touch current <100μA.  Both the ITE and Medical versions are available with output voltages ranging from 12V to 60V.

Features

  • ITE/Medical applications
  • Universal input 90VAC to 264VAC
  • Cost effective
  • Green Power
  • Small size
  • Single output

Applications

  • ITE/Medical application
  • Telecommunication
  • PCB power
  • Battery charging system
wdt_ID Part No. Safety Input Type Output Voltage Wattage Size (mm) Size (in) EMI Standby Loss PFC PDF SPECS 3D PDF 3D CAD IGS/STEP
1 DGK060-7 IT -UL/EN 60950-1 90 - 264 Vac Open-Frame Single 12V 60W 50.8 x 101.6 mm 2.0 x 4.0 in Class B <0.5W None PDF SPECS 3D PDF 3D CAD IGS/STEP
2 DGK060-8 IT -UL/EN 60950-1 90 - 264 Vac Open-Frame Single 15V 60W 50.8 x 101.6 mm 2.0 x 4.0 in Class B <0.5W None PDF SPECS 3D PDF 3D CAD IGS/STEP
3 DGK060-9 IT -UL/EN 60950-1 90 - 264 Vac Open-Frame Single 24V 60W 50.8 x 101.6 mm 2.0 x 4.0 in Class B <0.5W None PDF SPECS 3D PDF 3D CAD IGS/STEP
4 DGK060-14 IT -UL/EN 60950-1 90 - 264 Vac Open-Frame Single 48V 60W 50.8 x 101.6 mm 2.0 x 4.0 in Class B <0.5W None PDF SPECS 3D PDF 3D CAD IGS/STEP
5 DGK060-G IT -UL/EN 60950-1 90 - 264 Vac Open-Frame Single 28V 60W 50.8 x 101.6 mm 2.0 x 4.0 in Class B <0.5W None PDF SPECS 3D PDF 3D CAD IGS/STEP
6 DGK060-H IT -UL/EN 60950-1 90 - 264 Vac Open-Frame Single 60V 60W 50.8 x 101.6 mm 2.0 x 4.0 in Class B <0.5W None PDF SPECS 3D PDF 3D CAD IGS/STEP
7 DGK060-J IT -UL/EN 60950-1 90 - 264 Vac Open-Frame Single 36V 60W 50.8 x 101.6 mm 2.0 x 4.0 in Class B <0.5W None PDF SPECS 3D PDF 3D CAD IGS/STEP
8 DGK060M-14 IT -UL/EN 60950-1, Medical -UL/EN 60601-1 90 - 264 Vac Open-Frame Single 48V 60W 50.8 x 101.6 mm 2.0 x 4.0 in Class B <0.5W None PDF SPECS 3D PDF 3D CAD IGS/STEP
9 DGK060M-7 IT -UL/EN 60950-1, Medical -UL/EN 60601-1 90 - 264 Vac Open-Frame Single 12V 60W 50.8 x 101.6 mm 2.0 x 4.0 in Class B <0.5W None PDF SPECS 3D PDF 3D CAD IGS/STEP
10 DGK060M-8 IT -UL/EN 60950-1, Medical -UL/EN 60601-1 90 - 264 Vac Open-Frame Single 15V 60W 50.8 x 101.6 mm 2.0 x 4.0 in Class B <0.5W None PDF SPECS 3D PDF 3D CAD IGS/STEP
11 DGK060M-9 IT -UL/EN 60950-1, Medical -UL/EN 60601-1 90 - 264 Vac Open-Frame Single 24V 60W 50.8 x 101.6 mm 2.0 x 4.0 in Class B <0.5W None PDF SPECS 3D PDF 3D CAD IGS/STEP
12 DGK060M-G IT -UL/EN 60950-1, Medical -UL/EN 60601-1 90 - 264 Vac Open-Frame Single 28V 60W 50.8 x 101.6 mm 2.0 x 4.0 in Class B <0.5W None PDF SPECS 3D PDF 3D CAD IGS/STEP
13 DGK060M-H IT -UL/EN 60950-1, Medical -UL/EN 60601-1 90 - 264 Vac Open-Frame Single 60V 60W 50.8 x 101.6 mm 2.0 x 4.0 in Class B <0.5W None PDF SPECS 3D PDF 3D CAD IGS/STEP
14 DGK060M-J IT -UL/EN 60950-1, Medical -UL/EN 60601-1 90 - 264 Vac Open-Frame Single 36V 60W 50.8 x 101.6 mm 2.0 x 4.0 in Class B <0.5W None PDF SPECS 3D PDF 3D CAD IGS/STEP

NOTES: Contact factory for Safety Agency Approved status.

  1. Each output can provide up to max load separately when the power supply starts up. Exceeding the max. output power continuously is not allowed.
  2. At factory, in 60% rated load condition, each output is checked to be within voltage accuracy.
  3. Line regulation is defined by changing ± 10% of input voltage from nominal line at rated load.
  4. Load regulation is defined by changing ± 40% of measured output load from 60% rated load at another output set to 60% rated load.
  5. The ripple and noise is measured by using a 15MHz bandwidth limited oscilloscope. Each output is terminated with a 0.47 µF capacitor at rated load and nominal line.
  6. Hold up time is measured from the end of the last charging pulse to the time when the main output drops down to the low limit output of the main output at rated load and nominal line.
  7. Efficiency is measured at rated load and nominal load.

Contact us today, and have all your power supply needs met fast.