If you need a small, powerful single output power supply built with the exacting standards required of medical and IT equipment in mind, look no further than the DG080 series. The DG080 series delivers continuous 80 Watt power, with peak supply of 120 Watts. With a footprint of only 2” x 4”, it’s a high density power supply solution perfect for printed circuit boards.

The DG080 is tremendously efficient, with typical electrical efficiency rating above 88%, earning it Green Energy approval. Designed to run at peak efficiency between 20°C (-4°F) and 50°C (122°F), the DG080 will safely operate at temperatures up to 70°C (158°F), and has a safe storage temperature range between -40°C and 85°C (-40°F - 185°F).

The DG080 is double insulated, isolating the DC output from AC input, mitigating the risk of shock from component failure and earning a Class II safety rating. Tri-Mag is the leading manufacturer of power supplies and electrical components purpose-built for medical and IT equipment specifications.

Contact our electrical component manufacturers for more information on the DG080 Series power supplies, or call 559-651-2222 today to place your order.

Features

  • Universal Voltage Input 90 – 264VAC
  • High Power Density
  • “Green” power
  • Small Size
  • Single Output
  • Class II Safety & EMC
                            

Applications

  • ITE & Medical equipment
  • Telecommunications
  • PCB Power
  • Battery Charging System

Electrical Components Manufacturer Contact

NOTES: Contact factory for Safety Agency Approved status.

  1. Each output can provide up to max load separately when the power supply starts up. Exceeding the max. output power continuously is not allowed.
  2. At factory, in 60% rated load condition, each output is checked to be within voltage accuracy.
  3. Line regulation is defined by changing ± 10% of input voltage from nominal line at rated load.
  4. Load regulation is defined by changing ± 40% of measured output load from 60% rated load at another output set to 60% rated load.
  5. The ripple and noise is measured by using a 15MHz bandwidth limited oscilloscope. Each output is terminated with a 0.47 µF capacitor at rated load and nominal line.
  6. Hold up time is measured from the end of the last charging pulse to the time when the main output drops down to the low limit output of the main output at rated load and nominal line.
  7. Efficiency is measured at rated load and nominal line.
Part No.SafetyInput OutlookOutputVoltageWattageSize (mm)Size (in)EMIStandby LossPFCPDF SPECS3D PDF3D CAD IGS/STEP
DG080-3Industrial/IT -UL/EN 60950-10-264 VACOpen-FrameSingle18V80W50.8 x 101.6 mm2.0 x 4.0 inClass BN/ANonen/an/a
DG080-3-MMedical -UL/EN 60601-10-264 VACOpen-FrameSingle18V80W50.8 x 101.6 mm2.0 x 4.0 inClass BN/ANonen/an/a
DG080-7Industrial/IT -UL/EN 60950-10-264 VACOpen-FrameSingle12V80W50.8 x 101.6 mm2.0 x 4.0 inClass BN/ANonen/an/a
DG080-7-MMedical -UL/EN 60601-10-264 VACOpen-FrameSingle12V80W50.8 x 101.6 mm2.0 x 4.0 inClass BN/ANonen/an/a
DG080-8Industrial/IT -UL/EN 60950-10-264 VACOpen-FrameSingle15V80W50.8 x 101.6 mm2.0 x 4.0 inClass BN/ANonen/an/a
DG080-8-MMedical -UL/EN 60601-10-264 VACOpen-FrameSingle15V80W50.8 x 101.6 mm2.0 x 4.0 inClass BN/ANonen/an/a
DG080-9Industrial/IT -UL/EN 60950-10-264 VACOpen-FrameSingle24V80W50.8 x 101.6 mm2.0 x 4.0 inClass BN/ANonen/an/a
DG080-9-MMedical -UL/EN 60601-10-264 VACOpen-FrameSingle24V80W50.8 x 101.6 mm2.0 x 4.0 inClass BN/ANonen/an/a
DG080-TIndustrial/IT -UL/EN 60950-10-264 VACOpen-FrameSingle48V80W50.8 x 101.6 mm2.0 x 4.0 inClass BN/ANonen/an/a
DG080-T-MMedical -UL/EN 60601-10-264 VACOpen-FrameSingle48V80W50.8 x 101.6 mm2.0 x 4.0 inClass BN/ANonen/an/a