DG200 Series

DG200 Series

Compact does not mean unimpressive when it comes to power suppliers. The DG200 Series manufactured by Tri-Mag is small and powerful. A 3” x 5” x 1.5” Open Frame produces 200 Watts of power, with 8.9 Watts per cubic inch.

Each unit has a built in Active Power Factor Correction and the efficiency of this series ranges from 89% to 91%, depending on the model. There’s little wasted energy with this series. Tri-Mag’s eco-friendliness comes in the form of compliance with Green Power and the California Energy Commission (CFC). The cooling system is rated at 200 Watts via free air convection and up to 300 Watts with 24CFM forced air.

Overload protection up to 150% rated load means you’re covered in case of a power surge. This series comes with an optional metal enclosure keeping the incredible technology safe from harm. If you work in IT, telecom or the medical field, the DG200 Series is the power supply solution you want.

Contact our electrical component manufacturers at 559-651-2222 for more information on our DG200 Series power supplies or to place your order today.

Features

  • High Efficiency
  • Active PFC
  • Single Output
  • Universal input 90VAC to 264VAC
                            

Applications

  • IT Applications
  • Medical Applications
  • Telecommunications
  • Test Instrumentation Product
  • Data Acquisition
  • Other Applications

Electrical Components Manufacturer Contact

NOTES:

  1. Output Load: Convection cooling: 200W, forced-air cooling: 300W max
  2. Peak Load Duration: 400W peak rating for durations up to 5 secs. (Duty cycle < 10%, avg. power <200W)
  3. Engineering Specification: Contact Tri-Mag for full engineering specification for the specific part number used in your design application.
  4. Standby Power Consumption with System: This is required by ENERGY STAR in U.S. and ErP regulation in Europe for appliances such as computers and displays. The latest requirement is measured input power to be less than 0.5W with system.
  5. Audible Noise: For the DG120 (M)-x energy saving series, achieving Level VI (< 0.3W) standby power consumption is accomplished through burst mode operation of the controller. The burst operation frequency is dependent on load conditions and is approx. 114Hz, within the audible frequency range.
  6. Step Efficiency and Average Efficiency: Test conditions in step efficiency are referred to 3.2.2 IPS (Internal Power Supply) of the ENERGY STAR program requirements for computers. ENERGY STAR required for efficiency @ 20%, 50%, 100% load is 84.5%, 89%, 86.5%; average efficiency is the average of step efficiency.
Part No.SafetyInput OutlookOutputVoltageWattageSize (mm)Size (in)EMIStandby LossPFCPDF SPECS3D PDF3D CAD IGS/STEP
DG200M-14Industrial/IT -UL/EN 60950-1, Medical -UL/EN 60601-190-264 VACOpen-FrameSingle48V200W76.2 x 127.0 mm3.0 x 5.0 inClass B<0.5WYes
DG200M-14ECIndustrial/IT -UL/EN 60950-1, Medical -UL/EN 60601-190-264 VACEnclosed CaseSingle48V180W83.8 x 127.0 mm3.3 x 5.0 inClass B<0.5WYes
DG200M-14EUIndustrial/IT -UL/EN 60950-1, Medical -UL/EN 60601-190-264 VACU-Channel CaseSingle48V200W83.8 x 127.0 mm3.3 x 5.0 inClass B<0.5WYes
DG200M-3Industrial/IT -UL/EN 60950-1, Medical -UL/EN 60601-190-264 VACOpen-FrameSingle18V200W76.2 x 127.0 mm3.0 x 5.0 inClass B<0.5WYes
DG200M-3ECIndustrial/IT -UL/EN 60950-1, Medical -UL/EN 60601-190-264 VACEnclosed CaseSingle18V180W83.8 x 127.0 mm3.3 x 5.0 inClass B<0.5WYes
DG200M-3EUIndustrial/IT -UL/EN 60950-1, Medical -UL/EN 60601-190-264 VACU-Channel CaseSingle18V200W83.8 x 127.0 mm3.3 x 5.0 inClass B<0.5WYes
DG200M-7Industrial/IT -UL/EN 60950-1, Medical -UL/EN 60601-190-264 VACOpen-FrameSingle12V200W76.2 x 127.0 mm3.0 x 5.0 inClass B<0.5WYes
DG200M-7ECIndustrial/IT -UL/EN 60950-1, Medical -UL/EN 60601-190-264 VACEnclosed CaseSingle12V180W83.8 x 127.0 mm3.3 x 5.0 inClass B<0.5WYes
DG200M-7EUIndustrial/IT -UL/EN 60950-1, Medical -UL/EN 60601-190-264 VACU-Channel CaseSingle12V200W83.8 x 127.0 mm3.3 x 5.0 inClass B<0.5WYes
DG200M-8Industrial/IT -UL/EN 60950-1, Medical -UL/EN 60601-190-264 VACOpen-FrameSingle15V180W76.2 x 127.0 mm3.0 x 5.0 inClass B<0.5WYes
DG200M-8ECIndustrial/IT -UL/EN 60950-1, Medical -UL/EN 60601-190-264 VACEnclosed CaseSingle15V180W83.8 x 127.0 mm3.3 x 5.0 inClass B<0.5WYes
DG200M-8EUIndustrial/IT -UL/EN 60950-1, Medical -UL/EN 60601-190-264 VACU-Channel CaseSingle15V180W83.8 x 127.0 mm3.3 x 5.0 inClass B<0.5WYes
DG200M-9Industrial/IT -UL/EN 60950-1, Medical -UL/EN 60601-190-264 VACOpen-FrameSingle24V200W76.2 x 127.0 mm3.0 x 5.0 inClass B<0.5WYes
DG200M-9ECIndustrial/IT -UL/EN 60950-1, Medical -UL/EN 60601-190-264 VACEnclosed CaseSingle24V180W83.8 x 127.0 mm3.3 x 5.0 inClass B<0.5WYes
DG200M-9EUIndustrial/IT -UL/EN 60950-1, Medical -UL/EN 60601-190-264 VACU-Channel CaseSingle24V200W83.8 x 127.0 mm3.3 x 5.0 inClass B<0.5WYes
DG200M-GIndustrial/IT -UL/EN 60950-1, Medical -UL/EN 60601-190-264 VACOpen-FrameSingle28V200W76.2 x 127.0 mm3.0 x 5.0 inClass B<0.5WYes
DG200M-GECIndustrial/IT -UL/EN 60950-1, Medical -UL/EN 60601-190-264 VACEnclosed CaseSingle28V180W83.8 x 127.0 mm3.3 x 5.0 inClass B<0.5WYes
DG200M-GEUIndustrial/IT -UL/EN 60950-1, Medical -UL/EN 60601-190-264 VACU-Channel CaseSingle28V200W83.8 x 127.0 mm3.3 x 5.0 inClass B<0.5WYes
DG200M-JIndustrial/IT -UL/EN 60950-1, Medical -UL/EN 60601-190-264 VACOpen-FrameSingle36V200W76.2 x 127.0 mm3.0 x 5.0 inClass B<0.5WYes
DG200M-JECIndustrial/IT -UL/EN 60950-1, Medical -UL/EN 60601-190-264 VACEnclosed CaseSingle36V180W83.8 x 127.0 mm3.3 x 5.0 inClass B<0.5WYes
DG200M-JEUIndustrial/IT -UL/EN 60950-1, Medical -UL/EN 60601-190-264 VACU-Channel CaseSingle36V200W83.8 x 127.0 mm3.3 x 5.0 inClass B<0.5WYes
DG200-14ECIndustrial/IT -UL/EN 60950-10-264 VACEnclosed CaseSingle48V180W83.8 x 127.0 mm3.3 x 5.0 inClass B<0.5WYes
DG200-7Industrial/IT -UL/EN 60950-10-264 VACOpen-FrameSingle12V200W76.2 x 127.0 mm3.0 x 5.0 inClass B<0.5WYes
DG200-9ECIndustrial/IT -UL/EN 60950-10-264 VACEnclosed CaseSingle24V180W83.8 x 127.0 mm3.3 x 5.0 inClass B<0.5WYes