DG160 Series

DG160 Series

If you’re looking for a power supplier in a small package, the DG160 Series manufactured by Tri-Mag is the ideal choice. The compact 3” x 5” x 1.42” design provides 8.9 Watts per cubic inch inside of its 160 Watt open frame. Each unit has a built in Active Power Factor Correction, which allows this series to run between 89% and 91% efficiency, depending on the model. That’s incredible power in a small package, and it’s compliant with Green Power and the California Energy Commission (CFC) standards.

A cooling rating of 160 Watts free air convection and up to 240 Watts with 24CFM forced air delivers the perfect power source for telecom, IT, and medical applications. It can also be used for data applications, as well as testing instrumentation.

This series comes with an optional metal enclosure ensuring your investment is properly protected. An overload protection up to 150% rated load delivers a safeguard against voltage spikes. Make the DG160 Series your power supplier today!

Contact the power supplies manufacturers at Tri-Mag today for more information on our DG160 Series, or call 559-651-2222 to place your order today.

Features

  • High Efficiency
  • Active PFC
  • Single Output
  • Universal input 90VAC to 264VAC
                            

Applications

  • IT Applications
  • Medical Applications
  • Telecommunications
  • Test Instrumentation Product
  • Data Acquisition
  • Other Applications

Electrical Components Manufacturer Contact

NOTES:

  1. Output Load: Convection cooling: 160W, forced-air cooling: 240W max
  2. Peak Load Duration: 360W peak rating for durations up to 5 secs. (Duty cycle < 10%, avg. power < 160W)
  3. Engineering Specification: Contact Tri-Mag for full engineering specification for the specific part number used in your design application.
  4. Standby Power Consumption with System: This is required by ENERGY STAR in U.S. and ErP regulation in Europe for appliances such as computers and displays. The latest requirement is measured input power to be less than 0.5W with system.
  5. Audible Noise: For the DG160 (M)-x energy saving series, achieving Level VI (< 0.3W) standby power consumption is accomplished through burst mode operation of the controller. The burst operation frequency is dependent on load conditions and is approx. 114Hz, within the audible frequency range.
  6. Step Efficiency and Average Efficiency: Test conditions in step efficiency are referred to 3.2.2 IPS (Internal Power Supply) of the ENERGY STAR program requirements for computers. ENERGY STAR required for efficiency @ 20%, 50%, 100% load is 84.5%, 89%, 86.5%; average efficiency is the average of step efficiency.
Part No.SafetyInput OutlookOutputVoltageWattageSize (mm)Size (in)EMIStandby LossPFCPDF SPECS3D PDF3D CAD IGS/STEP
DG160M-14Industrial/IT -UL/EN 60950-1, Medical -UL/EN 60601-190-264 VACOpen-FrameSingle48V160W76.2 x 127.0 mm3.0 x 5.0 inClass B<0.5WYes
DG160M-14ECIndustrial/IT -UL/EN 60950-1, Medical -UL/EN 60601-190-264 VACEnclosed CaseSingle48V160W83.8 x 127.0 mm3.3 x 5.0 inClass B<0.5WYes
DG160M-14EUIndustrial/IT -UL/EN 60950-1, Medical -UL/EN 60601-190-264 VACU-Channel CaseSingle48V160W83.8 x 127.0 mm3.3 x 5.0 inClass B<0.5WYes
DG160M-3Industrial/IT -UL/EN 60950-1, Medical -UL/EN 60601-190-264 VACOpen-FrameSingle18V160W76.2 x 127.0 mm3.0 x 5.0 inClass B<0.5WYes
DG160M-3ECIndustrial/IT -UL/EN 60950-1, Medical -UL/EN 60601-190-264 VACEnclosed CaseSingle18V160W83.8 x 127.0 mm3.3 x 5.0 inClass B<0.5WYes
DG160M-3EUIndustrial/IT -UL/EN 60950-1, Medical -UL/EN 60601-190-264 VACU-Channel CaseSingle18V160W83.8 x 127.0 mm3.3 x 5.0 inClass B<0.5WYes
DG160M-7Industrial/IT -UL/EN 60950-1, Medical -UL/EN 60601-190-264 VACOpen-FrameSingle12V160W76.2 x 127.0 mm3.0 x 5.0 inClass B<0.5WYes
DG160M-7ECIndustrial/IT -UL/EN 60950-1, Medical -UL/EN 60601-190-264 VACEnclosed CaseSingle12V160W83.8 x 127.0 mm3.3 x 5.0 inClass B<0.5WYes
DG160M-7EUIndustrial/IT -UL/EN 60950-1, Medical -UL/EN 60601-190-264 VACU-Channel CaseSingle12V160W83.8 x 127.0 mm3.3 x 5.0 inClass B<0.5WYes
DG160M-8Industrial/IT -UL/EN 60950-1, Medical -UL/EN 60601-190-264 VACOpen-FrameSingle15V160W76.2 x 127.0 mm3.0 x 5.0 inClass B<0.5WYes
DG160M-8ECIndustrial/IT -UL/EN 60950-1, Medical -UL/EN 60601-190-264 VACEnclosed CaseSingle15V160W83.8 x 127.0 mm3.3 x 5.0 inClass B<0.5WYes
DG160M-8EUIndustrial/IT -UL/EN 60950-1, Medical -UL/EN 60601-190-264 VACU-Channel CaseSingle15V160W83.8 x 127.0 mm3.3 x 5.0 inClass B<0.5WYes
DG160M-9Industrial/IT -UL/EN 60950-1, Medical -UL/EN 60601-190-264 VACOpen-FrameSingle24V160W76.2 x 127.0 mm3.0 x 5.0 inClass B<0.5WYes
DG160M-9ECIndustrial/IT -UL/EN 60950-1, Medical -UL/EN 60601-190-264 VACEnclosed CaseSingle24V160W83.8 x 127.0 mm3.3 x 5.0 inClass B<0.5WYes
DG160M-9EUIndustrial/IT -UL/EN 60950-1, Medical -UL/EN 60601-190-264 VACU-Channel CaseSingle24V160W83.8 x 127.0 mm3.3 x 5.0 inClass B<0.5WYes
DG160M-GIndustrial/IT -UL/EN 60950-1, Medical -UL/EN 60601-190-264 VACOpen-FrameSingle28V160W76.2 x 127.0 mm3.0 x 5.0 inClass B<0.5WYes
DG160M-GECIndustrial/IT -UL/EN 60950-1, Medical -UL/EN 60601-190-264 VACEnclosed CaseSingle28V160W83.8 x 127.0 mm3.3 x 5.0 inClass B<0.5WYes
DG160M-GEUIndustrial/IT -UL/EN 60950-1, Medical -UL/EN 60601-190-264 VACU-Channel CaseSingle28V160W83.8 x 127.0 mm3.3 x 5.0 inClass B<0.5WYes
DG160-3Industrial/IT -UL/EN 60950-10-264 VACOpen-FrameSingle18V160W76.2 x 127.0 mm3.0 x 5.0 inClass B<0.5WYes
DG160-7Industrial/IT -UL/EN 60950-10-264 VACOpen-FrameSingle12V160W76.2 x 127.0 mm3.0 x 5.0 inClass B<0.5WYes
DG160-7ECIndustrial/IT -UL/EN 60950-10-264 VACEnclosed CaseSingle12V160W83.8 x 127.0 mm3.3 x 5.0 inClass B<0.5WYes
DG160-7EUIndustrial/IT -UL/EN 60950-10-264 VACU-Channel CaseSingle12V160W83.8 x 127.0 mm3.3 x 5.0 inClass B<0.5WYes
DG160-8Industrial/IT -UL/EN 60950-10-264 VACOpen-FrameSingle15V160W76.2 x 127.0 mm3.0 x 5.0 inClass B<0.5WYes
DG160-8ECIndustrial/IT -UL/EN 60950-10-264 VACEnclosed CaseSingle15V160W83.8 x 127.0 mm3.3 x 5.0 inClass B<0.5WYes