DT060AF Series

DT060 Series

DT060AF Series External Power Supply

The DT060AF Series is a 60W external power supply (EPS) designed for both medical and ITE applications. The eco-friendly design is compliant with the new DOE Energy Conservation Standards for External Power Supplies.

With a 150% (90W) peak power rating, operating efficiencies >89% and no-load input power <0.15W, the DT060AF Series is ideal for ITE and medical equipment designs, including MOOP and 2X MOPP, that are compliant with 2016 conservation standards.

Contact Tri-Mag today by calling 559-651-2222 for more information on our custom power supply components.

Features

  • Level VI Energy Compliant
  • No Load Input Power < 0.15W
  • Average Efficiency > 89%
  • Eco-Friendly Design
  • UL/CSA/EN 60950-1 and UL/CSA/EN 60601-1 3rd Edition Compliant
                            

Applications

  • ITE
  • Medical
  • Other Applications

Electrical Components Manufacturer Contact

NOTES:

  1. Output Load: Rated 60W for convection cooling.
  2. Peak Load Duration: 90W peak rating for durations up to 5 sec. Ideal for motor-starting/in-rush conditions.
  3. Engineering Specification: Contact Tri-Mag for full engineering specification for the specific part number used in your design application.
  4. Standby Power Consumption with System: New external power supply (EPS) efficiency requirements have been established by the U.S. DOE (EPS) and the European ErP regulations. The no-load power consumption requirements are < 0.21W and < 0.15W respectively.
  5. Audible Noise: For the DT060AF-x energy saving series, achieving level VI (< 0.15W) standby power consumption is accomplished through burst mode operation of the controller. The burst operation frequency is dependent on load conditions and is approx. 114Hz, within the audible frequency range.
  6. Step Efficiency and Average Efficency: Test conditions in step efficiency are referred to 3.2.2 IPS (Internal Power Supply) of ENERGY STAR program requirements for computers. ENERGY STAR required for efficiency @ 20%, 50%, 100% load is 90%, 91%, 89%; average efficiency is the average of step efficiency.
Part No.SafetyInput OutlookOutputVoltageWattageSize (mm)Size (in)EMIStandby LossPFCPDF SPECS3D PDF3D CAD IGS/STEP
DT060AF-14Industrial/IT -UL/EN 60950-1, Medical -UL/EN 60601-10-264 VACAdapterSingle48V60W65.0 x 1352.6 x 5.3Class B<0.15WNone
DT060AF-5Industrial/IT -UL/EN 60950-1, Medical -UL/EN 60601-10-264 VACAdapterSingle12V60W65.0 x 1352.6 x 5.3Class B<0.15WNone
DT060AF-6Industrial/IT -UL/EN 60950-1, Medical -UL/EN 60601-10-264 VACAdapterSingle24V60W65.0 x 1352.6 x 5.3Class B<0.15WNone
DT060AF-8Industrial/IT -UL/EN 60950-1, Medical -UL/EN 60601-10-264 VACAdapterSingle15V60W65.0 x 1352.6 x 5.3Class B<0.15WNone