DHF060 Series

DHF060 Series

DHF060 Series Open-Frame Power Supply

The DHF060 Series is a 60W, open-frame, Level 6 compliant power supply that is a compact 2.0” x 3.17” x 0.95” in size. In addition to being an eco-friendly design, the series has an expanded, -40°C to +70°C, operating temperature range and is rated to an operating altitude of 5,000m.

The series has a 90W peak-power rating making it ideal for motor-starting/in-rush currents for ITE and Medical equipment, including MOOP and 2X MOPP, applications.

Contact the power supply manufacturers at Tri-Mag for your power supply needs at 559-651-2222.

Features

  • 2" x 3.17" x 0.95" Compact Size
  • 5,000m Operating Attitude
  • -40°C to 70°C Convection Cooling Operation
  • Up to 12,000uF Loading Start-Up
  • Level 6 Compliant Eco-Friendly Design
                            

Applications

  • IT
  • Medical
  • Data Acquisition
  • Telecommunications
  • Other Applications

Electrical Components Manufacturer Contact

NOTES:

  1. Output Load: Convection cooling: 60W, forced-air cooling: 72W max
  2. Peak Load Duration: 96W peak rating for durations up to 5 secs. Ideal for motor starting/in-rush conditions.
  3. Engineering Specification: Contact Tri-Mag for full engineering specification for the specific part number used in your design application.
  4. Standby Power Consumption with System: This is required by ENERGY STAR in U.S. and ErP regulation in Europe for appliances such as computers and displays. The latest requirement is measured input power to be less than 0.5W with system.
  5. Audible Noise: For the DHF060-x energy saving series, achieving Level VI (< 0.3W) standby power consumption is accomplished through burst mode operation of the controller. The burst operation frequency is dependent on load conditions and is approx. 114Hz, within the audible frequency range.
  6. Step Efficiency and Average Efficiency: Test conditions in step efficiency are referred to 3.2.2 IPS (Internal Power Supply) of the ENERGY STAR program requirements for computers. ENERGY STAR required for efficiency @ 20%, 50%, 100% load is 82%, 85%, 86%; average efficiency is the average of step efficiency.
Part No.SafetyInput OutlookOutputVoltageWattageSize (mm)Size (in)EMIStandby LossPFCPDF SPECS3D PDF3D CAD IGS/STEP
DHF060-14Industrial/IT -UL/EN 60950-1, Medical -UL/EN 60601-10-264 VACOpen-FrameSingle48V60W50.8 x 80.52.0 x 3.2Class B<0.3WNone
DHF060-7Industrial/IT -UL/EN 60950-1, Medical -UL/EN 60601-10-264 VACOpen-FrameSingle12V60W50.8 x 80.52.0 x 3.2Class B<0.3WNone
DHF060-7AIndustrial/IT -UL/EN 60950-1, Medical -UL/EN 60601-10-264 VACOpen-FrameSingle12V60W50.8 x 80.52.0 x 3.2Class B<0.5WNone
DHF060-8Industrial/IT -UL/EN 60950-1, Medical -UL/EN 60601-10-264 VACOpen-FrameSingle15V60W50.8 x 80.52.0 x 3.2Class B<0.3WNone
DHF060-8AIndustrial/IT -UL/EN 60950-1, Medical -UL/EN 60601-10-264 VACOpen-FrameSingle15V60W50.8 x 80.52.0 x 3.2Class B<0.5WNone
DHF060-9Industrial/IT -UL/EN 60950-1, Medical -UL/EN 60601-10-264 VACOpen-FrameSingle24V60W50.8 x 80.52.0 x 3.2Class B<0.3WNone
DHF060-9AIndustrial/IT -UL/EN 60950-1, Medical -UL/EN 60601-10-264 VACOpen-FrameSingle24V60W50.8 x 80.52.0 x 3.2Class B<0.5WNone
DHF060-14AIndustrial/IT -UL/EN 60950-1, Medical -UL/EN 60601-10-264 VACOpen-FrameSingle48V60W50.8 x 80.52.0 x 3.2Class B<0.5WNone