DHF030 Series

DHF030 Series

DHF030 Series Open-Frame Power Supply

The DHF030 Series is a 30W, open-frame, Level 6 compliant power supply that is a compact 1.57” x 2.76” x 0.9” in size. In addition to being an eco-friendly design, the series has an expanded, -40°C to +70°C, operating temperature range and is rated to an operating altitude of 5,000m.

The series has a 45W peak-power rating making it ideal for motor-starting/in-rush currents for ITE and Medical equipment, including MOOP and 2X MOPP, applications.

Contact the power supply manufacturers at Tri-Mag at 559-651-2222 today, and have all your power supply needs met fast.

Features

  • 1.57" x 2.76" x 0.9" Compact Size
  • Flexible Installation for Class I/II
  • 5,00m Operating Altitude
  • -40°C to 70°C Convection Cooling Operation
  • Up to 12,000uF Loading Start-Up
  • Level 6 Compliant Eco-Friendly Design
                            

Applications 

  • Medical
  • IT
  • Data Acquisition
  • Other Applications

Electrical Components Manufacturer Contact

NOTES:

  1. Output Load: Convection cooling: 30W, forced-air cooling: 36W
  2. Peak Load Duration: 45W peak rating for durations up to 5 secs. Ideal for motor starting/in-rush conditions.
  3. Engineering Specification: Contact Tri-Mag for full engineering specification for the specific part number used in your design application.
  4. Standby Power Consumption with System: This is required by ENERGY STAR in U.S. and ErP regulation in Europe for appliances such as computers and displays. The latest requirement is measured input power to be less than 0.5W with system.
  5. Audible Noise: For the DHF030-x energy saving series, achieving Level VI (< 0.3W) standby power consumption is accomplished through burst mode operation of the controller. The burst operation frequency is dependent on load conditions and is approx. 114Hz, within the audible frequency range.
  6. Step Efficiency and Average Efficiency: Test conditions in step efficiency are referred to 3.2.2 IPS (Internal Power Supply) of the ENERGY STAR program requirements for computers. ENERGY STAR required for efficiency @ 20%, 50%, 100% load is 82%, 85%, 86%; average efficiency is the average of step efficiency.
Part No.SafetyInput OutlookOutputVoltageWattageSize (mm)Size (in)EMIStandby LossPFCPDF SPECS3D PDF3D CAD IGS/STEP
DHF030-14Industrial/IT -UL/EN 60950-1, Medical -UL/EN 60601-10-264 VACOpen-FrameSingle48V30W40.0 x 70.01.6 x 2.8Class B<0.3WNone
DHF030-14AIndustrial/IT -UL/EN 60950-1, Medical -UL/EN 60601-10-264 VACOpen-FrameSingle48V30W40.0 x 70.01.6 x 2.8Class B<0.5WNone
DHF030-7Industrial/IT -UL/EN 60950-1, Medical -UL/EN 60601-10-264 VACOpen-FrameSingle12V30W40.0 x 70.01.6 x 2.8Class B<0.3WNone
DHF030-7AIndustrial/IT -UL/EN 60950-1, Medical -UL/EN 60601-10-264 VACOpen-FrameSingle12V30W40.0 x 70.01.6 x 2.8Class B<0.5WNone
DHF030-8Industrial/IT -UL/EN 60950-1, Medical -UL/EN 60601-10-264 VACOpen-FrameSingle15V30W40.0 x 70.01.6 x 2.8Class B<0.3WNone
DHF030-8AIndustrial/IT -UL/EN 60950-1, Medical -UL/EN 60601-10-264 VACOpen-FrameSingle15V30W40.0 x 70.01.6 x 2.8Class B<0.5WNone
DHF030-9Industrial/IT -UL/EN 60950-1, Medical -UL/EN 60601-10-264 VACOpen-FrameSingle24V30W40.0 x 70.01.6 x 2.8Class B<0.3WNone
DHF030-9AIndustrial/IT -UL/EN 60950-1, Medical -UL/EN 60601-10-264 VACOpen-FrameSingle24V30W40.0 x 70.01.6 x 2.8Class B<0.5WNone